How to Compare TPU Coiled Cable Specifications Before RFQ

Before ordering a custom TPU coiled cable, confirm stretch length, rebound, TPU hardness, connector strain relief, testing, packaging and RFQ details.

When buyers request custom TPU coiled cables, a product name is not enough to produce a comparable quotation. Two cables described as a TPU spiral cable can differ in relaxed length, normal working extension, conductor assignment, shielding, connector orientation and packaging. Put those details on one RFQ checklist so suppliers review the same requirements before sampling.

Quick Answer

Compare TPU coiled cable specifications in this order: application and circuit function; relaxed length and working extension; coil and straight-tail dimensions; conductors and shielding; connector and pinout; environment; sample acceptance checks; and quantity and packaging. A maximum stretch value is not a substitute for the reach needed during normal operation. If a drawing is not ready, send equipment photos, approximate dimensions, a wiring description and estimated quantity for an initial review.

Why a Quote Can Miss the Requirement

A short RFQ such as “custom spring cable, 3 core” leaves essential choices unresolved. It does not explain what each conductor does, how far the cable must reach in routine use, which connector view defines the pin numbers, or what the buyer will inspect on the sample. Suppliers may therefore make different assumptions, so their prices and lead-time estimates are not directly comparable.

TPU coiled cable and TPU spiral cable are common names for a retractile cable format. The name alone does not confirm the material grade, electrical rating, environmental suitability or finished-assembly performance. Those points need to be stated in the drawing or reviewed and agreed for the project.

Specification Comparison Checklist

1. Define the application and circuit

Describe the equipment, fixed and moving endpoints, movement path and electrical purpose. List each conductor’s function at both ends. For a 2-core design, document both paths; for a 3-core design, assign all three. Never assume that the third core is ground or protective earth without the approved wiring design. The 2-core vs 3-core buyer comparison explains what to confirm.

2. Separate relaxed length from working extension

Record the relaxed coil length after an agreed conditioning state, the normal working extension used in the equipment, and any temporary maximum extension as separate values. Define whether the measurement includes connectors and straight tails. Include both tail lengths, coil outside diameter, active coil length, pitch if controlled, and cable outside diameter. These dimensions help a supplier evaluate reach, storage space and routing without treating the cable as a straight lead.

3. State conductor and shielding requirements

Specify conductor count, material or construction if controlled, gauge or cross-sectional area, color identification and circuit duty. If shielding is required, identify the intended shield construction or the interference problem, drain-wire arrangement, grounding point and connector-shell termination. Do not use the word “shielded” as a complete electrical requirement. The finished build should be reviewed against the buyer’s circuit and acceptance method.

4. Identify connectors and pinout

Provide connector manufacturer and part number when known, mating part, keying, contact assignment, viewing direction, orientation and cable exit direction. Include a wiring diagram or annotated connector photo. State whether overmolding, a protective cap, locking or a specific strain-relief shape is required. A connector image by itself may not identify the mating interface or pin numbering.

5. Describe the actual environment

List the operating conditions that matter to the application, such as abrasion points, movement frequency, liquids, cleaning agents, sunlight, storage and temperature range. If the project has a required ingress, chemical or endurance target, name the assembly state, test method and acceptance limit. TPU as a material name does not establish a universal rating for the finished cable and connectors.

6. Agree sample checks before ordering

Choose measurable checks from the approved drawing and equipment requirement. A sample plan may cover continuity and pinout, specified electrical checks, dimensions, connector mating, visual condition, working extension and return behavior. State how the sample is positioned, measured and conditioned, and what constitutes acceptance. This is a proposed checklist, not a claim that every test is included or has already been performed.

Common Specification Mistakes

  • Giving only a maximum stretched length and omitting relaxed length and normal working reach.
  • Writing “2 core” or “3 core” without assigning every conductor to a circuit and pin.
  • Providing a connector photo without a part number, mating part, orientation or pinout.
  • Requesting shielding or environmental performance without a termination plan or test method.
  • Comparing quotes that use different dimensions, inspection scope, order quantities or packaging.
  • Approving the sample by appearance without checking it in the intended routing or fixture.

Buyer Checklist for a Comparable RFQ

  • Application, equipment photos and movement path.
  • Circuit function, conductor count, gauge and wiring diagram.
  • Relaxed length, normal working extension, coil diameter and straight tails.
  • Connector part numbers, mating interfaces, orientation and pinout.
  • Shielding and grounding requirements, if applicable.
  • Operating environment and project-specific test method.
  • Sample quantity, estimated order quantity, labels and packaging.

Explore Configurations and Send an RFQ

Browse the TPU coiled cable and spiral cable range for the main product selection hub, then compare 2-core, 3-core and shielded TPU cable starting points. The final construction must still match the approved project specification.

For a sample review, see the stretch and rebound approval checklist and the photographed batch length-inspection and packaging case. The case documents visible inspection and packing steps; it does not claim a customer identity or a TPU-specific performance result.

Send a drawing, wiring diagram, connector photos, approximate dimensions, application and quantity through Upload RFQ. If the drawing is not ready, photos and basic requirements are enough to start a specification review.