Custom TPU Coiled Cables: 9 Specifications to Confirm Before RFQ

Nine specifications buyers should confirm before requesting a custom TPU coiled cable quotation or sample.

Quick Answer: A useful custom TPU coiled cable RFQ defines the circuit, conductor construction, relaxed and working lengths, coil space, terminations, environment, quantities, and sample acceptance method. Custom designs with 2–15 insulated conductors can be evaluated, subject to engineering review of the complete cable and connector combination.

1. Describe the Application

Identify the equipment, fixed and moving connection points, movement path, installation space, and reason for using a coil. A marked photo or simple sketch helps distinguish normal operation from an occasional reach condition.

2. Define Each Conductor’s Function

State the conductor count and map every conductor between the two ends. Separate power, signal, data, control, reference, and protective functions as specified by the equipment design. Core count alone does not define current capacity, voltage rating, or compliance.

For 2-core and 3-core starting configurations, compare the 2-core TPU coiled cable and 3-core TPU coiled cable. For the decision factors, see the 2-core vs. 3-core buyer guide. Higher conductor counts and mixed circuit designs require review of wire size, insulation, shielding, coil diameter, and termination space.

3. Select Wire Gauge from the Circuit Requirements

Provide the electrical design’s current, voltage, signal type, allowable resistance or voltage drop, and relevant installation conditions. The engineer should confirm the conductor size and cable construction against those requirements; do not choose a gauge from core count or appearance alone.

4. Specify Relaxed Length

Give the length in the agreed resting condition and state whether the measurement includes straight tails or connector bodies. Mark the measurement points so the sample and production inspection use the same method.

5. Separate Working Extension from Maximum Extension

State the reach used during normal operation separately from any temporary maximum. Describe the pull direction and movement frequency. Approving only a maximum straightened length can lead to an assembly that is uncomfortable or puts unnecessary load on the equipment connector.

6. Dimension the Coil and Straight Tails

Provide coil inside or outside diameter as required by the installation, coiled-section length, cable outside diameter constraint, pitch if controlled, and each straight-tail length. Show exit directions and the space available around the coil. These dimensions should be reviewed together, not as unrelated catalog values.

7. Identify Connectors, Pinout, and Termination

List manufacturer part numbers or approved equivalents, mating parts, keying, pin numbering view, wire-to-pin mapping, overmold envelope, and exit orientation. Photos are useful, but they do not replace a controlled pinout or connector reference.

8. State Shielding and Environment Requirements

Describe the signal or noise concern, preferred shield construction if specified, drain-wire arrangement, connector-shell termination, and grounding path. Also list actual exposure such as abrasion points, oils or cleaning agents, moisture, temperature range, and movement pattern. The engineering team should review the selected material and finished assembly against the stated environment.

For a shielded starting point, see the shielded TPU coiled cable page.

9. Define Quantity, Packaging, and Sample Approval

Provide prototype/sample quantity, expected order volume, labeling and packaging requirements, and the target approval process. Agree which checks apply to the sample, such as dimensions in a defined condition, connector mating, visual finish, continuity and pin mapping, and return behavior. These are proposed checks, not a claim that a particular test has already been performed.

Common RFQ Mistakes

  • Sending only a maximum stretched length.
  • Listing a conductor count without assigning circuit functions.
  • Omitting gauge, connector part numbers, pinout, or shield termination.
  • Assuming a generic extension ratio or material grade guarantees the result.
  • Comparing quotes with different drawing revisions, test scope, or packaging.
  • Approving a sample without checking it in the real routing path.

Buyer Checklist

  • Application sketch, fixed/moving points, and operating environment.
  • Conductor count, circuit map, gauge requirement, and shielding details.
  • Relaxed length, normal working extension, coil dimensions, and straight tails.
  • Connector references, mating parts, orientation, and pinout.
  • Sample quantity, acceptance criteria, annual demand, labeling, and packaging.

Request an Engineering Review

The TPU coiled cable product range covers available starting configurations; final combinations depend on engineering review. Send your drawing, sample photos, circuit functions, dimensions, connector references, and expected quantity through Upload RFQ. If a drawing is not ready, provide the information available and identify what still needs confirmation.