Quick answer: A custom TPU spiral cable RFQ should define the cable’s relaxed length, normal working extension, temporary maximum extension, coil outside diameter and pitch, straight-tail lengths, conductor design, connector and pinout, expected recovery, test method and packaging. These values must come from the buyer’s application; a product photo cannot establish them.
Why Quotes Differ for the Same “TPU Coiled Cable”
TPU coiled cable and TPU spiral cable usually describe the same retractable form. Suppliers may nevertheless quote different coil geometries, cable constructions and connector assemblies. If one quote assumes a longer working extension or a different strain relief, the prices and sample results are not directly comparable. Use one controlled drawing and one RFQ revision for all suppliers.
Dimensions to Put on the Drawing
| Parameter | Buyer should state | Sample check |
|---|---|---|
| Relaxed length | End-to-end length at rest and whether tails are included | Measure after an agreed rest period |
| Working extension | Length routinely needed in the installed equipment | Check reach and handling force in the application |
| Temporary maximum | Occasional extension limit and intended duration | Inspect recovery and connector stress afterward |
| Coil geometry | Outside diameter, pitch, number of turns and tolerances | Compare sample dimensions with the approved drawing |
| Straight tails | Length at each end and connector exit direction | Check mounting clearance and bend at the exit |
Conductors, Shielding and Connector Details
Identify conductor count and gauge, power or signal function, shielding or twisted pairs where required, jacket material, color and the intended environment. Give exact mating connector part numbers when available, plus pinout, keying, orientation, overmold and strain-relief requirements. If equivalent components are permitted, specify who approves the substitution and how the revision is recorded.
How to Approve Stretch and Rebound
- Record initial dimensions and the state of the sample before testing.
- Define the normal working extension, cycle method and number of repetitions based on actual use.
- Measure return length after a stated rest period; document the allowed difference in the drawing or test plan.
- Inspect coil shape, jacket surface, straight tails and connector exits; check continuity and pinout after cycling.
- Keep the approved sample and results as the reference for the production build. Agree on any ongoing inspection frequency before ordering.
Do not accept an unsupported “stretch ratio” or “cycle life” as a universal TPU performance claim. Material grade, cable construction and use conditions determine what a particular assembly can achieve.
Packaging and Commercial Questions
Ask how coils will be restrained without permanent deformation, how connectors are protected, and how models and pinouts are labeled. Provide sample quantity, forecast demand, target market and delivery destination. MOQ and lead time should be quoted for the approved construction, tooling and packaging, not copied from a generic catalog entry.
RFQ Checklist to Send
- Application photo or drawing, mounting arrangement and movement description.
- All relaxed, working and maximum dimensions with measurement conditions.
- Conductor design, connector part numbers, pinout, jacket and environment.
- Test method, sample acceptance limits and production inspection records.
- Packaging, labels, quantity, target market and requested schedule.
Start with the TPU coiled cable product range, then compare application details on the robot sensor coiled cable page or test instrument coiled cable page. The robot sensor specification example shows how buyers can frame movement and shielding questions; it is illustrative, not a completed customer project. Upload a drawing or send an RFQ when the initial parameters are ready.